UBG-16 Specifications

16 Input Channels

Besides EGT and CHT, the UBG-16 is capable of accepting inputs from TIT, OAT, Carb Temp, any other temperature, Manifold Pressure, RPM, Volts, Amps, Oil Pressure, Oil Temperature, Fuel Flow, Fuel Pressure, and Gyro Vacuum Pressure.

34 Programmable Limits

16 Programmable Upper Limits – One for each Input Channel, 16 Programmable Lower Limits – One for each Input Channel, Programmable EGT Differential Limit, Programmable CHT Shock Cooling Limit.

Scan Rate

Programmable from 1 to 9 Seconds per Channel

Mount

2.25″

Depth

5.35″

Weight

Instrument Only: 19 Oz.
Probe and 6′ Cable: 3.5 Oz.
Probe and 10′ Cable: 7 Oz.

Resolution

1 Degree (Fahrenheit)

Accuracy

1/2%.

Display

Plasma, adjustable dimness for night operations

Power Requirements

7.5 to 35 volts, at .3 amps